-40%

OMRON CJ1M-CPU11 PLC CPU UNIT Controllers CPU 5k PROG 32k DATA MEMORY New in Box

$ 184.25

Availability: 74 in stock
  • Item must be returned within: 60 Days
  • MPN: Does Not Apply
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Type: PLC
  • Return shipping will be paid by: Seller
  • Condition: New
  • All returns accepted: Returns Accepted
  • Brand: OMRON
  • Model: CJ1M-CPU11

    Description

    Welcome To Fibica
    Follow Daily Mart on:
    OMRON CJ1M-CPU11 PLC CPU UNIT Controllers CPU 5k PROG 32k DATA MEMORY New in Box
    Product Description
    OMRON CJ1M-CPU11 PLC CPU UNIT Controllers CPU 5k PROG 32k DATA MEMORY New in Box
    Availability:
    Customize
    Usually Ships within 2-4days
    Any Questions:
    Chat with a Specialist >
    Feel free to contact our specialist for any compatibiltiy problems.
    Close Notes
    Quantity:
    1
    Buy it Now
    If you have any questions, please inform us by eBay message.
    Close Notes
    Product Detail
    Why Daily Mart ?
    Payment Method
    International Shipping
    Return & Warranty
    Product Specification:
    Control method
    Stored program
    I/O control method
    Cyclic scan and immediate processing are both possible.
    Programming
    LD (Ladder), SFC (Sequential Function Chart), ST (Structured Text), Mnemonic
    CPU processing mode
    CJ1M CPU Units: Normal Mode or Peripheral Servicing Priority Mode
    Instruction length
    1 to 7 steps per instruction
    Ladder instructions
    Approx. 400 (3-digit function codes)
    Execution time
    CJ1M CPU Units (CPU12/13/22/23):
    Basic instructions: 0.10 µs min.
    Special instructions: 0.15 µs min.
    CJ1M CPU Units (CPU11/21):
    Basic instructions: 0.10 µs min.
    Special instructions: 0.15 µs min.
    Overhead time
    CJ1M CPU Units (CPU12/13/22/23): 0.5 ms min.
    CJ1M CPU Units (CPU11/21): 0.7 ms min.
    Unit connection method
    No Backplane: Units connected directly to each other.
    Mounting method
    DIN Track (screw mounting not possible)
    Maximum number of
    connectable Units
    CJ1M CPU Units:
    Total of 20 Units in the System, including 10 Units on CPU Rack and 10 Units on one Expansion Rack.
    Maximum number of
    Expansion Racks
    CJ1M CPU Units (CPU 13/23 only):
    1 max. (An I/O Control Unit is required on the CPU Rack and an I/O Interface Unit is required on the Expansion
    Rack.)
    CJ1M CPU Units (CPU11/12/21/22):
    Expansion is not possible.
    Number of tasks
    288 (cyclic tasks: 32, interrupt tasks: 256)
    With CJ1M CPU Units, interrupt tasks can be defined as cyclic tasks called "extra cyclic tasks." Including
    these, up to 288 cyclic tasks can be used.
    Note 1.
    Cyclic tasks are executed each cycle and are controlled with TKON(820) and TKOF(821) instructions.
    Note 2.
    The following 4 types of interrupt tasks are supported.
    Power OFF interrupt tasks: 1 max.
    Scheduled interrupt tasks: 2 max.
    I/O interrupt tasks: 32 max.
    External interrupt tasks: 256 max.
    Interrupt types
    Scheduled Interrupts:
    Interrupts generated at a time scheduled by the CPU Unit's built-in timer. (See note. 1)
    I/O Interrupts: Interrupts from Interrupt Input Units.
    Power OFF Interrupts (See note 2.): Interrupts executed when the CPU Unit's power is turned OFF.
    External I/O Interrupts: Interrupts from the Special I/O Units or CPU Bus Units.
    Note 1.
    CJ1M CPU Units: Scheduled interrupt time interval is 0.5 ms to 999.9 ms (in increments of 0.1 ms), 1 ms to
    9,999 ms (in increments of 1 ms), or 10 ms to 99,990 ms (in increments of 10 ms)
    Note 2.
    Not supported when the CJ1W-PD022 Power Supply Unit is mounted.
    Function blocks (CPU
    Unit with unit version
    3.0 or later only)
    Languages in function block definitions: ladder programming, structured text
    CIO
    (Core
    I/O)
    Area
    I/O Area
    1,280: CIO 000000 to CIO 007915 (80 words from CIO 0000 to CIO 0079)
    The setting of the first word can be changed from the default (CIO 0000) so that CIO 0000
    to CIO 0999 can be used.
    I/O bits are allocated to Basic I/O Units.
    The CIO Area
    can be used as
    work bits if the
    bits are not
    used as shown
    here.
    Link Area
    3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to CIO 1199)
    Link bits are used for data links and are allocated to Units in Controller Link Systems.
    CPU Bus Unit
    Area
    6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to CIO 1899)
    CPU Bus Unit bits store the operating status of CPU Bus Units.
    (25 words per Unit, 16 Units max.)
    Special I/O Unit
    Area
    15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000 to CIO 2959)
    Special I/O Unit bits are allocated to Special I/O Units. (10 words per Unit, 96 Units max.)
    Note:
    Special I/O Units are I/O Units that belong to a special group called "Special I/O Units."
    Example: CJ1W-AD081 Analog Input Unit
    Serial PLC Link
    Area (CJ1M CPU
    Units only)
    1,440 (90 words): CIO 310000 to CIO 318915 (words CIO 3100 to CIO 3189)
    DeviceNetArea
    9,600 (600 words): CIO 320000 to CIO 379915 (words CIO 3200 to CIO 3799)
    DeviceNet bits are allocated to Slaves for DeviceNet Unit remote I/O communications
    when the Master function is used with fixed allocations.
    Fixed allocation setting 1
    Outputs: CIO 3200 to CIO 3263
    Inputs: CIO 3300 to CIO 3363
    Fixed allocation setting 2
    Outputs: CIO 3400 to CIO 3463
    Inputs: CIO 3500 to CIO 3563
    Fixed allocation setting 3
    Outputs: CIO 3600 to CIO 3663
    Inputs: CIO 3700 to CIO 3763
    The following words are allocated to the Master function even when the DeviceNet Unit
    is used as a Slave.
    Fixed allocation setting 1
    Outputs: CIO 3370 (Slave to Master)
    Inputs: CIO 3270 (Master to Slave)
    Fixed allocation setting 2
    Outputs: CIO 3570 (Slave to Master)
    Inputs: CIO 3470 (Master to Slave)
    Fixed allocation setting 3
    Outputs: CIO 3770 (Slave to Master)
    Inputs: CIO 3670 (Master to Slave)
    Internal I/O
    Area
    4,800 (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)
    37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 to CIO 6143)
    These bits in the CIO Area are used as work bits in programming to control program execution. They cannot
    be used for external I/O.
    Work Area
    8,192 bits (512 words): W00000 to W51115 (W000 to W511)
    Controls the programs only. (I/O from external I/O terminals is not possible.)
    Note: When using work bits in programming, use the bits in the Work Area first before using bits from other
    areas.
    Holding Area
    8,192 bits (512 words): H00000 to H51115 (H000 to H511)
    Holding bits are used to control the execution of the program, and maintain their ON/OFF status when the
    PLC is turned OFF or theoperating mode is changed.
    Note: The Function Block Holding Area words are allocated from H512 to H1535. These words can be used
    only for the function block instance area (internally allocated variable area).
    Auxiliary Area
    Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)
    Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)
    Auxiliary bits are allocated specific functions.
    Temporary Area
    16 bits (TR0 to TR15)
    Temporary bits are used to temporarily store the ON/OFF execution conditions at program branches.
    Timer Area
    4,096: T0000 to T4095 (used for timers only)
    Counter Area
    4,096: C0000 to C4095 (used for counters only)
    DM Area
    32 Kwords: D00000 to D32767
    Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the DM Area
    maintain their status when the PLC is turned OFF or the operating mode is changed.
    Internal Special I/O Unit DM Area: D20000 to D29599 (100 words ?96 Units)
    Used to set parameters for Special I/O Units.
    CPU Bus Unit DM Area: D30000 to D31599 (100 words ?16 Units)
    Used to set parameters for CPU Bus Units.
    Index Registers
    IR0 to IR15
    Store PLC memory addresses for indirect addressing. Index registers can be used independently in each task.
    One register is 32 bits (2words).
    CJ1M CPU Units: Setting to use index registers either independently in each task or to share them between
    tasks.
    Task Flag Area
    32 (TK0000 to TK0031)
    Task Flags are read-only flags that are ON when the corresponding cyclic task is executable and OFF when
    the corresponding task is not executable or in standby status.
    Trace Memory
    4,000 words (trace data: 31 bits, 6 words)
    File Memory
    Memory Cards: Compact flash memory cards can be used (MS-DOS format).
    Package Include:
    1 x OMRON CJ1M-CPU11 PLC CPU UNIT Controllers CPU 5k PROG 32k DATA MEMORY New in Box
    6 months warranty
    60 days money back
    Life-time support.
    Our specialists will be with you during shopping and after-sell. Professional advise and any technical problem will be provided. We will respond any question within
    24-hour
    normally. Please allow longer time for weekend.
    Our logistic team will pack your order safely, make sure the item will be arrived perfectly. And then the parcels will be pass to courier. The total dispatched time will be around
    1-2 days
    .
    We focus on product quality, rather than packaging and marketing, in order to deliver the
    finest quality
    of product at a fraction cost. We believe that you would like to pay for the item cost except unnecessary costs.
    Our product team will keep the products
    up-to-date
    , which can allows you to purchase the latest and valuable products from our stores. We believe our
    Wide Product Range
    will be your selection.
    How should I make my payment ?
    We accept
    PayPal
    . Your payment is protected by
    Buyer Protection
    .
    Items will be shipped within
    1-2 working days
    of payment being made.
    No mailing payment will be accepted.
    window.NREUM||(NREUM={});NREUM.info={"beacon":"bam-cell.nr-data.net","licenseKey":"32933b6325","applicationID":"66754545","transactionName":"ZgEAMkVZXEVZUEFdXV9LNxReF1ZTS1BHXUJFDQ0IGUhaRg==","queueTime":0,"applicationTime":148,"atts":"SkYDRA1DT0s=","errorBeacon":"bam-cell.nr-data.net","agent":""}